[. . . ] [. . . ] I. D 12. 8
±1. 5
45
120 R SC 90±5
269. 3 ±3
Rated Performance
Capacity Motor Input Current EER 11, 000 Btu/h 1, 038 W 9. 5 A 10. 6 Btu/W. h 3, 223 Watts
224. 3
220 118. 5 50. 8
3. 11 W/W
Compressor Data
38. 6 2. 3
Design Displacement Oil / Oil Charge Weight Rolling Piston Typed Rotary 15. 6 cc/rev 0. 95 in3 /rev SUNISO 4GSI / 280 cc 11. 5 Kg 25. 4 lb
258. 6
±3
150 3 - 19. 1
Motor Data
Motor Type Voltage Range Locked Rotor Amps. 2 Pole Induction (PSC) 97 V to 132 V Not Fixed
Detail of
15. 9
7. 5
Detail of
10. 0 0. 5
Electrical Components
Running Capacitor Overload Protector 50 370 VAC MRA 12053 - 12026 (T. I Korea) - Not Fixed
Compressor Mounting
Bolt, Stud Nut, Hexagon Comp. Tri-plate Grommet Unit Base Washer, Plain 28 mm (1. 10 inch) Line
19. 1 35
Wiring Diagram
O. L. P C S R Compressor
Capacity Test Conditions
Evaporating Condensing Return Gas Liquid Ambient Temp. 7. 2 54. 4 35. 0 46. 1 35. 0 45 130 95 115 95
Running Capacitor
C. S. R mark is embossed on a Cover Terminal
Specifications are subject to change without notice. [. . . ] [. . . ]